{"title":"eBay Listings","description":"","products":[{"product_id":"racor-ccv4500-engine-air-filtration-crankcase-ventilation-filter-7761","title":"Racor CCV4500 Engine Air Filtration Crankcase Ventilation Filter 7761 model CV4501-04","description":"\u003cp\u003eClosed Crankcase Ventilation Assemblies 0-400 HP, Left and Right\u003c\/p\u003e\n\u003cul class=\"fs-list--cleaner\"\u003e\n\u003cli class=\"ng-star-inserted\"\u003eCaptures Oil Blow-By\u003c\/li\u003e\n\u003cli class=\"ng-star-inserted\"\u003eReturns Oil to the Crankcase\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNew, never installed. Packaging is dirty\u003c\/p\u003e\n\u003cp\u003eRACOR CCV4500-08L Closed crankcase ventilation systems are designed for your turbo charged engine to provide superior oil coalescence and crankcase pressure control under the most severe conditions. It reduces NOx and hydrocarbon emissions by lowering combustion temperatures.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.parker.com\/content\/dam\/Parker-com\/Literature\/Racor-Europe\/FDRB558UK_BRO_Crankcase_Ventilation_Products_and_Solutions.pdf\"\u003eCrankcase Ventilation Products and Solutions Brochure\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.parker.com\/content\/dam\/Parker-com\/Literature\/Racor\/RSL\/RSL0327_CUT_CCV4500-CCV4501.pdf\"\u003eSpecifications\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.parker.com\/content\/dam\/parker\/pfg\/engine-mobile-original-equipment-division\/resources\/instructions\/55021_CCV_Series.pdf\"\u003eInstallation Instructions for CCV4500\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003eSKU 124359 - CVV4500-08R and CVV4500-08L or \u003ca href=\"https:\/\/ph.parker.com\/us\/en\/product\/crankcase-ventilation-systems\/cv4501-04l\"\u003eCCV4500-04L\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eClosed Crankcase Ventilation systems capture engine blow-by oil and gases (normally discharged into your engine room, or the environment), and deliver them back into the oil sump. The result is a markedly cleaner engine room, and no noticeable oil smell in the salon or cockpit. CCVs can also markedly reduce turbo whine.\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan\u003eEspecially suited for turbo-charged diesels, Racor CCVs provide superior oil coalescence and crankcase pressure control under the most severe conditions. They also reduce NOx and hydrocarbon emissions by lowering combustion temperatures.\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan\u003e• High efficiency filter with integral pressure regulator and Vaporbloc filter\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Pressure regulator with integral bypass valve that minimizes variation in pressure\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Pop-up style indicator alerts operator for filter change\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Operating temperatures: -40°F to 240°F\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Typical service life is 750 hours\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"expand1_borderTop__rs4cn mt-5\"\u003e\n\u003cdiv class=\"flex\"\u003e\n\u003ch2 class=\"bold nowrap\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cspan class=\"expand1_expandIcon1__Ot4Qp font-size-xx-large-Blk\"\u003e\u003ci class=\"fas fa-minus\" aria-hidden=\"true\"\u003e\u003c\/i\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003csection\u003e\n\u003cdiv class=\"MuiGrid-root MuiGrid-container css-1d3bbye\"\u003e\n\u003cdiv class=\"MuiGrid-root MuiGrid-item MuiGrid-grid-xs-12 MuiGrid-grid-lg-12 MuiGrid-grid-xl-12 tableSplit css-15j76c0\"\u003e\n\u003ctable id=\"table1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"font-size-medium-Blk bold\"\u003eFiltration Ratings:\u003c\/td\u003e\n\u003ctd class=\"font-size-small-Blk pl-2\"\u003eLow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"font-size-medium-Blk bold\"\u003eInlet Location:\u003c\/td\u003e\n\u003ctd class=\"font-size-small-Blk pl-2\"\u003eLeft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"font-size-medium-Blk bold\"\u003eBrand:\u003c\/td\u003e\n\u003ctd class=\"font-size-small-Blk pl-2\"\u003eRacor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"font-size-medium-Blk bold\"\u003eProduct Series:\u003c\/td\u003e\n\u003ctd class=\"font-size-small-Blk pl-2\"\u003eCartridge Crankcase Ventilation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"font-size-medium-Blk bold\"\u003eFor Fluid Type:\u003c\/td\u003e\n\u003ctd class=\"font-size-small-Blk pl-2\"\u003eEngine Blowby Gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"font-size-medium-Blk bold\"\u003eMounting Type:\u003c\/td\u003e\n\u003ctd class=\"font-size-small-Blk pl-2\"\u003eIntegrated Head Bracket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"font-size-medium-Blk bold\"\u003eCompatible Element:\u003c\/td\u003e\n\u003ctd class=\"font-size-small-Blk pl-2\"\u003eLow: CCV55248-04\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"font-size-medium-Blk bold\"\u003ePort Size:\u003c\/td\u003e\n\u003ctd class=\"font-size-small-Blk pl-2\"\u003e1-3\/16\", 12 SAE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"font-size-medium-Blk bold\"\u003eDrain:\u003c\/td\u003e\n\u003ctd class=\"font-size-small-Blk pl-2\"\u003eDrain Kit: Hose, Check Valve, (2) Swivel Fitting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"font-size-medium-Blk bold\"\u003eIndicator Type:\u003c\/td\u003e\n\u003ctd class=\"font-size-small-Blk pl-2\"\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"font-size-medium-Blk bold\"\u003ePressure Regulator Type:\u003c\/td\u003e\n\u003ctd class=\"font-size-small-Blk pl-2\"\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"font-size-medium-Blk bold\"\u003eWidth:\u003c\/td\u003e\n\u003ctd class=\"font-size-small-Blk pl-2\"\u003e7.2 inch, 18.3 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"font-size-medium-Blk bold\"\u003eDepth:\u003c\/td\u003e\n\u003ctd class=\"font-size-small-Blk pl-2\"\u003e5.6 inch, 14.2 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"font-size-medium-Blk bold\"\u003eHeight:\u003c\/td\u003e\n\u003ctd class=\"font-size-small-Blk pl-2\"\u003e8.6 inch, 21.7 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"font-size-medium-Blk bold\"\u003eHeat Type:\u003c\/td\u003e\n\u003ctd class=\"font-size-small-Blk pl-2\"\u003e100W Optional: CCV55461 (120VAC) CCV55461-12 (12VDC) CCV55461-24 (24VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"font-size-medium-Blk bold\"\u003eType\/Configuration:\u003c\/td\u003e\n\u003ctd class=\"font-size-small-Blk pl-2\"\u003eOpen System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"font-size-medium-Blk bold\"\u003eMaximum Flow Rate:\u003c\/td\u003e\n\u003ctd class=\"font-size-small-Blk pl-2\"\u003e10 cfm \/ 0.28 m3\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"font-size-medium-Blk bold\"\u003eFunction:\u003c\/td\u003e\n\u003ctd class=\"font-size-small-Blk pl-2\"\u003eNon-Bypass Assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"font-size-medium-Blk bold\"\u003eMaximum Output:\u003c\/td\u003e\n\u003ctd class=\"font-size-small-Blk pl-2\"\u003e200HP \/ 149 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mt-1 mb-5\"\u003e\n\u003ci class=\"expand1_exclamatoryIcon__FF9Vm far fa-exclamation-triangle\" aria-hidden=\"true\"\u003e\u003c\/i\u003e\u003ca class=\"MuiTypography-root MuiTypography-inherit MuiLink-root MuiLink-underlineAlways expand1_linkElement__uAydS font-size-small-Blk ml-0 css-15kjgm\" href=\"https:\/\/ph.parker.com\/us\/en\/product\/crankcase-ventilation-systems\/cv4501-04l#safetywarning\"\u003eSafety Warning\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mt-1 mb-5\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"expand2_borderTop__wOCOR\"\u003e\n\u003cdiv class=\"flex\"\u003e\n\u003ch2 class=\"bold nowrap\"\u003eItem Information\u003c\/h2\u003e\n\u003cspan class=\"expand2_expandIcon2__aiY5I font-size-xx-large-Blk\"\u003e\u003ci class=\"fas fa-minus\" aria-hidden=\"true\"\u003e\u003c\/i\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003csection\u003e\n\u003cdiv id=\"ReadMore\"\u003e\n\u003cp\u003eCrankcase blow-by gas is produced when combustion gases under high pressure escape past piston rings into the crankcase. As these blow-by gases pass though the crankcase, they become contaminated with oil mist. In enclosed areas, like generator sets or engine rooms, the contaminated gas coats and damages surrounding equipment, resulting in hazardous conditions and the need for costly maintenance. Uncontrolled blow-by oil mist also coats engine after-coolers and turbochargers, which reduces cooling capacity and engine efficiency.\u003cbr\u003e\u003cbr\u003eRacor's Crankcase Ventilation Systems prevent this problem by removing mist and contamination in blow-by gases. In closed systems (CCV), the high efficiency filter prevents fouling of the turbocharger and after-cooler. In open systems (CV), it prevents fouling of surrounding equipment and walls, thus allowing clean exhaust to vent directly to the atmosphere.\u003cbr\u003e\u003cbr\u003eThe systems have stainless steel latches for tool-less element change and a metal housing (steel for the 4500 unit and aluminum for 6000, 8000 \u0026amp; 12000 units) with an epoxy powder coating. They also have a drain check valve, which allows collected oil to return to the crankcase, resulting in drastically reduced oil consumption.\u003cbr\u003e\u003cbr\u003eOpen systems are acceptable for certain engines and situations. However, in recent years, environmental concerns and legislation to control crankcase emissions have increased significantly. New laws to further reduce the total emissions of engines often make it necessary to close the crankcase breather system. In this case, blow-by gases are routed into the inlet of the turbocharger where they can be burned instead of polluting the environment.\u003cbr\u003e\u003cbr\u003eHow they work:\u003cbr\u003e\u003cbr\u003eCV Series (Open Crankcase Ventilation Systems) - Racor's CV (open) system filters are high-efficiency oil separators, featuring depth-loading, micro-glass fiber Vaporbloc™ media, which is capable of coalescing vapor and contaminants down to 0.3 microns. The resulting filtered and coalesced oil is held in a hose line with a check valve until it can be released to the oil pan via a hose connection. Filtered gasses are released to the atmosphere. The units are designed to handle crankcase flow rates up to 50 cfm (1.42 m3\/m) or more when using multiple units.\u003cbr\u003e\u003cbr\u003eCCV Series (Closed Crankcase Ventilation Systems) - Racor's CCV (closed) systems also utilize depth-loading, micro-glass fiber Vaporbloc™ media. In these systems, blow-by gasses are not allowed to vent to the atmosphere. Instead, the cleaned and filtered gases are routed back to the inlet of the turbocharger to be burned in the engine. The units are designed to handle crankcase flow rates up to 50 cfm (1.42 m3\/m) or more when using multiple units. CCV units feature a unique crankcase pressure regulator with an integral bypass valve. This regulator protects against crankcase over-pressure and under-pressure, thus preventing damage to seals and oil loss.\u003cbr\u003e\u003cbr\u003eUse in Marine Applications - Marine diesel engines can benefit from the installation of a combination CCV and air filter\/silencer system. The CCV contains Racor's high-performance Vaporbloc™ filter media. Marine air filter\/silencers (AF Series) contain washable media and are ruggedly built to provide extended service life.\u003cbr\u003e\u003cbr\u003eWhen installed, the engine crankcase breather is connected to the inlet of the Racor CCV Assembly. The CCV outlet is connected to the engine's combustion air inlet via an air intake connector where filtered blow-by gas is recycled through the combustion process. Oil collected in the CCV sump is returned to the crankcase through a hose and a drain check valve.\u003cbr\u003e\u003cbr\u003eNotes on use:\u003cbr\u003e\u003cbr\u003e• The only routine maintenance required for a Racor crankcase ventilation system is filter replacement. Typical service life of the high-performance filter in diesel applications is 750 hours. Some variations in service life occur depending on the load profile, engine wear conditions, flow, aerosol mass concentration of crankcase emissions, and soot concentration. The pop-up style indicator on the top of the CCV (closed system) unit alerts the operator when such a filter change is needed (remote indicator is available as an option: CCV55615-01.)\u003cbr\u003e\u003cbr\u003e• CV Series (open system) units do not have an over-pressure indicator so regular filter maintenance and crankcase pressure monitoring must be performed separately. Not following these requirements may lead to damaged seals and oil loss.\u003cbr\u003e\u003cbr\u003e• CV (open system) units are all “Non-Bypass”, and therefore as the filter plugs, crankcase pressure will increase. They can only be used if regular filter maintenance is performed and there are crankcase over-pressure safeguards in place. Not following these requirements may lead to damaged seals and oil loss.\u003cbr\u003e\u003cbr\u003e• “Non-Bypass” versions of the CCV (closed system) filters have the same limitation as the CV (open crankcase) units (i.e., as the filter plugs, crankcase pressure will increase). They can only be used if regular filter maintenance is performed and crankcase over pressure safeguards are in place. Not following these requirements may lead to damaged seals and oil loss.\u003cbr\u003e\u003cbr\u003eHow to select:\u003cbr\u003e\u003cbr\u003e1. Choose Open System or Closed System\u003cbr\u003e\u003cbr\u003e2. Choose flow rate required\u003cbr\u003e\u003cbr\u003eCrankcase flow rate can be obtained from the engine manufacturer, by direct measurement with a mass airflow sensor or through an approximate calculation. In a closed system, simply divide the rated horsepower (HP) by 40 to get cfm (rated kW\/30). In an open system, divide the rated horsepower by 20 (rated kW\/15). While various factors can alter the accuracy of this formula, such as modern piston improvements or engine wear, this is usually a good estimation of flow.\u003cbr\u003e\u003cbr\u003eFormulas for calculating crankcase blow-by flow are outlined below:\u003cbr\u003e\u003cbr\u003eClosed system: divide rated HP by 40 to get cfm. (kW\/1000 = m3\/m)\u003cbr\u003eOpen system: divide rated HP by 20 to get cfm. (kW\/500 – m3\/m)\u003cbr\u003e3. Choose bypass, non-bypass, or “intermittent duty” (1 cfm unit) function:\u003cbr\u003e4. Choose filter media density\/efficiency\u003cbr\u003e5. Choose Inlet on right or left side\u003cbr\u003e\u003cbr\u003eMarkets:\u003cbr\u003e\u003cbr\u003e• Agriculture\u003cbr\u003e• Construction\u003cbr\u003e• Power Generation\u003cbr\u003e• Oil and Gas\u003cbr\u003e• On- or Off-highway\u003cbr\u003e• Marine\u003cbr\u003e\u003cbr\u003eApplications:\u003cbr\u003e\u003cbr\u003e• Diesel Engines\u003cbr\u003e\u003cbr\u003eBenefits:\u003cbr\u003e\u003cbr\u003e• Prevents fouling of critical engine components, such as turbochargers and after-coolers by removing oil contamination from engine bypass gases.\u003cbr\u003e• Reduces operating costs and improves safety in enclosed areas, where contaminated gas from engines can coat and damage surrounding equipment, resulting in hazardous conditions and the need for costly maintenance.\u003cbr\u003e• Minimal maintenance requirements. Typical service life of the high-performance crankcase ventilation system in diesel applications is 750 hours.\u003cbr\u003e• Drain check valve allows collected oil to return to the crankcase, resulting in drastically reduced oil consumption.\u003cbr\u003e• Available in open (CV) or closed (CCV) configurations to meet the unique requirements of customers’ engines.\u003cbr\u003e• Suitable for use in marine applications. ‘\u003cbr\u003e\u003cbr\u003eFeatures:\u003cbr\u003e\u003cbr\u003e• Racor crankcase ventilation units for closed or open systems\u003cbr\u003e• High efficiency oil separation down to 0.3 micron\u003cbr\u003e• Unique crankcase pressure regulator\u003cbr\u003e• Replaceable high-performance filter\u003cbr\u003e• Depth loading, micro-glass fiber coalescing Vaporbloc™ media\u003cbr\u003e• Steel housing with epoxy powder coating\u003cbr\u003e• Drain check valve\u003cbr\u003e• Left or right inlet ports\u003cbr\u003e• Closed units offer bypass or non-bypass options\u003cbr\u003e• Closed units offer pop-up style, or remote indicator of bypass condition\u003cbr\u003e• Compatible with flow rates up to 50 cfm (1.42 m3\/m)\u003cbr\u003e• Continuous operating temperature range -40° to 240°F (-40°C to 116°C)\u003cbr\u003e\u003cbr\u003eOptional Kits:\u003cbr\u003e\u003cbr\u003e• CCV Fitting\/Hose Kits\u003cbr\u003e• CCV 90° Hose Adapters\u003cbr\u003e• CCV hose Barbs\u003cbr\u003e• Bulk Hose Kits\u003cbr\u003e• Hump Hose Fittings\u003cbr\u003e• CCV8000 Conversion Kits (covert to CCV12000)\u003cbr\u003e• CCV Heater Kits\u003cbr\u003e• Electronic Remote Filter Gauge\u003cbr\u003e• Heavy-Duty Wear Spacers\u003cbr\u003e• Tap Sleeves\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan class=\"font-size-medium-Blk bold\"\u003eEngine Mobile OE Division - North America\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eracortech@parker.com\u003cbr\u003e662 274 2124\u003cbr\u003e____________________\u003cbr\u003eEngine Mobile OE Division - Europe\u003cbr\u003e+44 (0) 1924 487 037\u003cbr\u003efiltrationinfo@parker.com\u003c\/p\u003e","brand":"Racor","offers":[{"title":"Right Inlet Side","offer_id":42014432559222,"sku":"124359","price":325.0,"currency_code":"USD","in_stock":false},{"title":"Left Inlet Side","offer_id":42014432591990,"sku":"93345","price":325.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1596\/7647\/files\/racor-closed-crankcase-ventilation-assemblies-0-400-hp-ccv4500-08l.jpg?v=1739930952"}],"url":"https:\/\/inclusivo.org.mx\/en\/collections\/ebay-listings.oembed","provider":"Inclusive Inc","version":"1.0","type":"link"}